Open chat

Electrical equipment and parts in bulk on Qoovee

Specify the price USD 0 0
This kind of cable has excellent low temperature resistance and abrasion resistance, as well as fatigue resistance and microbial resistance, and has excellent corrosion resistance to oils and chemicals. Reference standard: DIN VDE; Working voltage: 450/750V; Working temperature (fixed installation): -45℃~+110℃; Working temperature (mobile installation): -25℃~+110℃; Minimum bending radius: fixed installation: 4× outer diameter of cable, mobile installation: 5× outer diameter of cable Test AC withstand voltage: ≤0.75mm2 2000V ≥1mm2 3000V Cable structure: Conductor: conform to IEC60228 standard 5;          Insulation: Comply with VDE 0270 Part 20;          Core wire identification: black core wire and white numbers are consecutively numbered, with a yellow and green two-color ground wire;          Shielding: the braid density is not less than 85%.          Sheath: in line with VDE standards.
Specify the price USD 0 0
This kind of cable has excellent low temperature resistance and abrasion resistance, as well as fatigue resistance and microbial resistance, and has excellent corrosion resistance to oils and chemicals. Reference standard: DIN VDE; Working voltage: 0.6/1kV; Working temperature (fixed installation): -45℃~+110℃; Working temperature (mobile installation): -25℃~+110℃; Minimum bending radius: fixed installation: ≥4×outer diameter of cable, mobile installation: ≥5×outer diameter of cable; Torsion test: at -40℃, torsion 6000 times, each time is 4 weeks (1440º); Voltage test: 3500V/5 minutes. Cable structure: Conductor: conform to IEC60228 standard 5;            Insulation: Comply with VDE 0270 Part 20;            Sheath: in line with VDE standards.
Specify the price USD 0 0
Classification profile:     Products such as glass filament covered wire, glass filament coated enameled wire, glass filament covered film winding wire, glass filament covered polyester filament covered wire are special materials specially made for various types of motors, welding machines, and generator coils. DC resistance per unit length (R20)≤0.017241Ωmm2/m; self-adhesive performance requirements, after heating the sample for 20min, self-adhesive ≥2MPa; temperature grade: according to different needs, temperature grades are 130, 155, 180, etc.
Specify the price USD 0 0
Enameled rectangular wire is a winding wire made of oxygen-free copper rods or electrical round aluminum rods drawn or extruded by a certain specification die, and coated with insulating paint many times. Enameled rectangular copper wire can be used alone, or it can be made into enameled glass wire covered wire and other products. It is a material for the manufacture of transformers, motors, generators and coils of various electrical devices. According to different needs, the operating temperature is 120, 130, 155, 180, 200, 220ºC; DC resistance: DC resistance per unit length (R20)≦0.017241Ω mm2/m; electrical performance: at least 4 samples in each sample The breakdown voltage value meets the requirements of the following table, and the breakdown voltage value of one sample is not less than 5% of the value specified in the table below; Adhesion: After the sample is stretched as required, the distance where the paint film loses adhesion should Greater than 1b; Bending: After the sample is bent according to the standard, the paint film should not crack; Self-adhesive: After the sample is treated and cured according to the standard, the tensile force of the bonding surface should be greater than 4.5N/mm2.
Specify the price USD 0 0
Double polyester glass fiber sintered wire is a special material for the manufacture of large generator coils DC resistance: DC resistance value per unit length (R20)≦0.017241Ω mm2/m; Insulation flexibility: After the sample is bent according to the standard requirements, there should be no obvious cracking or falling off of the insulation layer
Specify the price USD 0 0
Product introduction: The combined wire can be composed of 2 or more flat winding wires in a wide-side or narrow-side overlapping arrangement. According to the combination and winding method, it can be divided into flat-stacked, side-by-side and force-stacked; then wrapped with specific insulating materials It is a product designed for the winding of large and medium-sized transformers. It can also be made into semi-hard combined wires. Product performance: 1. Nominal specifications of a single copper wire: side a: 1.0-5.0 side b: 2.0-16.0. 2. Insulation: If the user has no requirements for insulating paper varieties, our company will use DLZ cable paper for wrapping. 3. Withstand voltage: No breakdown between two adjacent single paper-covered wires subjected to a DC 200V voltage test. 4. DC resistance: (1) Soft-state DC resistance: The resistance value (R20) of a single core wire is not more than 0.017241Ω mm2/m. (2) Semi-hard DC resistance: Depending on the hardness, the resistance value (R20) of a single core wire is between 0.017241-0.01777 Ω mm2/m. 5. Resistance imbalance: The resistance imbalance between two adjacent single paper-covered wires is not more than 2%. 6. Nominal hardness value of semi-hard wire: σ0.2 rated value (N/mm2): 120, 150, 180, 200, 220
Specify the price USD 0 0
Product introduction: Ordinary paper covered wire is a special material for coil windings of oil-immersed transformers and similar electrical appliances. The temperature index after immersion is 105ºC. Using NOMEX paper wrapping can be used in the production of dry-type transformers, with a temperature index of 220ºC, and can also be made into semi-rigid paper-covered wires. According to user requirements, telephone paper, cable paper, high-voltage cable paper, turn-to-turn insulation paper, Denison paper, etc. can be used respectively. Specific instructions: 1. DC resistance: (1) Soft-state DC resistance value (R20) ≤0.017241Ω mm2/m. (2) The semi-hard DC resistance value is 0.017241-0.01777Ω mm2/m according to the hardness. 2. Winding and bending: After the sample is wound and bent according to the standard, the wrapping layer should not crack, show seams, and have no obvious warping edges. 3. Half hardness: σ0.2 rated value (N/mm2): 120, 150, 180, 200, 220
Specify the price USD 0 0
It is mainly suitable for the power system, control system and lighting system of offshore and land oil drilling platforms of 2000V and below. Oil drilling and production cables have been used in oil drilling projects and petrochemical projects, and the product performance has been well reflected. Special cables for oil drilling and production have excellent high and low temperature resistance, small bending radius, wear resistance, fatigue resistance, microbe resistance, hydrolysis resistance, oil resistance, chemical corrosion resistance and other properties.
Specify the price USD 0 0
Product model: CHJV, CHEV, CHJVP, CHEVP, CHVV80, CHJV80, CHEV80, CHVV90, CHJV90, CHEV90, CHVV82, CHJV82, CHEV82, CHVV92, CHJV92, CHEV92, CHJPJ, CHEPJ, CHJPF, CHEPF, CHJJ80, PJ80, PFCHE ,CHJPJP, CHEPJP, CHJPFP, CHEPFP, CHJPJ90, CHEPJ90, CHEPF90, CHJPF90, CHJPJ86, CHEPJ86, CHEPF85, CHJPF85, CHJPJ96, CHEPJ96, CHEPF95, CHJPF95, CHJPJ80, CHEPJ80, CHEPF80, CHJPFP80, CHJPJ96, CHEPJ96, CHEPF95, CHJPF95   Wire core and cross-section range: Pairing groups: 2, 3, 4 groups Number of cable cores: 1~48 cores Cross-section range: 0.3~2.5 mm2   Standards used: IEC 60092-375, IEC 60092-376, IEC60092-353   1. The cable is used in a DC or AC 60V system, and it can also be used normally at DC or AC 250V and below in case of failure. 2. Long-term allowable working temperature of the cable: 85℃.
Specify the price USD 0 0
Product number: CKVV,CKJV,CKEV, CKVV80,CKJV80,CKEV80, CKVV90,CKJV90,CKEV90, CKVV82,CKJV82,CKEV82, CKVV92,CKJV92,CKEV92,CKJPJ,CKEPJ, CKJPF,CKEP,JCK80,CKEP90 CKEPF90, CKJPF90, CKJPJ86, CKEPJ86, CKEPF85, CKJPF85, CKJPJ96, CKEPJ96, CKEPF95, CKJPF95   Number of cores, cross-section range: Number of cable cores: 2~37 cores Cable section: 0.5~2.5 mm2   Standards used: IEC 60754, IEC 61034, IEC60331, IEC 60092-376, IEC 60332 1. Rated voltage 250V 2. Long-term allowable working temperature of the cable:     Polyvinyl chloride insulation is 70℃;     Natural styrene butadiene rubber insulation is 70℃;     Cross-linked polyethylene and ethylene-propylene rubber insulation is 90℃;     Silicone rubber insulation is 180°C. 3. See the table below for the allowable bending radius of the cable when laying:     Cable structure characteristics Cable outer diameter Minimum bending inner radius     Metal braided armor type Any value 6D        Non-armoured type D≤25 4D                           D>25 6D 4. The minimum cable laying temperature; PVC sheath is -15℃, others are -20℃.
Specify the price USD 0 0
Product model: CVV, CJV, CEV, CVVR, CJVR, CEVR, CVV80, CJV80, CEV80, CVV90, CJV90, CEV90, CVV82, CJV82, CEV82, CVV92, CJV92, CEV92, CJPJ, CEPJ, CJPF, CEPF, CJPJR, CEPJR, CJPFR, CEPFR, CJPJ80, CEPJ80, CEPF80, CJPF80, CJPJ90, CEPJ90, CEPF90, CJPF90, CJPJ86, CEPJ86, CEPF85, CJPF85, CJPJ96, CEPJ96, CEPF95, CJPF95   Core section range: Number of cable cores: 1, 2, 3, 4, 5, 7, 10, 12, 14, 16, 19, 24, 27, 30, 33, 37 Cable section range: Single core: 1~300mm2; Two cores: 1~120 mm2; Three cores: 1~185 mm2; Four cores and above: 1~2.5 mm2   Standards used: IEC 60228, IEC 61034, IEC60754, IEC 60092-353, IEC 60331 1. Rated voltage U0/U: 0.6/1kV 2. Long-term allowable working temperature of the cable:    Polyvinyl chloride insulation is 70℃;    Natural styrene butadiene rubber insulation is 70℃;    Cross-linked polyethylene and ethylene-propylene rubber insulation is 90℃;    Silicone rubber insulation is 180°C. 3. Except for flexible cables that can be used by mobile devices, other cables are fixedly laid. The allowable bending radius of the cables when laying is as follows.    Cable structure characteristics Cable outer diameter Minimum bending inner radius    Metal braided armor type Any value 6D       Non-armoured type D≤25 4D                      D>25 6D 4. The minimum cable laying temperature; PVC sheath is -15℃, others are -20℃.
Specify the price USD 0 0
The WDZ-DCYJ-125 cable is suitable for use in environments where subway vehicles, rolling stock, etc. are relatively closed, with concentrated personnel, and where low-smoke and halogen-free performance is demanding. Particularly suitable for internal power distribution and power supply systems of subway vehicles and rolling stock. 1. Product model WDZ-DCYJ-125;   2. Executive standard: GBl 2528.11-2003, rated voltage: 500V, 750V, 1500V. 3000V.   3. Nominal cross section: O.75-300mm2;   4. Excellent temperature resistance: long-term working temperature is 125℃, short-circuit overload temperature can reach 250℃ (5s);   5. Excellent electrical insulation properties, physical and mechanical properties and high and low temperature resistance;   6. The flame retardant performance of the cable meets the requirements of GB/T18380.1-2001;   7. Excellent softness and wear resistance;   8. Excellent low-smoke and halogen-free characteristics;      1) Conductivity ≤10 u s/mm;      2) The light transmittance of smoke generated when the cable is burning is ≥60%;      3) PH value ≥ 4.3;      4) The halogen content is less than or equal to 5mg/g.
Specify the price USD 0 0
Mainly used in 750V and below power transmission and control systems such as various locomotives and railways. 1. Rated voltage: 750V 2. The long-term allowable working temperature of the cable conductor should not exceed 125°C. 3. Cable laying environment: the cable can be used in occasions contaminated by mineral oil and fuel oil. 4. Cable laying temperature:      The lowest ambient temperature for cable use is -40°C (dynamic use is -25°C), and the laying temperature is -25°C. 5. The inner bending radius of the laying is small:      When the cable outer diameter is not greater than 10mm, the inner bending radius should not be less than 2 times the cable diameter; when the cable outer diameter is greater than 10mm but not greater than 20mm, the inner bending radius should not be less than 4 times the cable diameter; when the cable outer diameter is greater than At 20mm, the inner bending radius should not be less than 6 times the cable diameter.
Specify the price USD 0 0
This product is suitable for wiring electrical equipment inside locomotives and vehicles with AC rated voltages of 3000V and below.It has a soft structure and can be used on locomotives and vehicles contaminated by mineral oil and fuel oil.
Specify the price USD 0 0
This special cable is produced according to the German DIN VDE standard. The cable has good low temperature resistance and abrasion resistance, as well as fatigue resistance, weathering resistance, microbial resistance, and corrosion resistance; it has excellent torsion and bending properties; The cable meets the ambient temperature -45℃~+110℃, the operating temperature is -40℃~+110℃; the cable laying temperature is not lower than -30℃; the power bending radius: fixed installation is not less than 4 times the cable outer diameter, mobile installation is not Less than 5 times the outer diameter of the cable.
Specify the price USD 0 0
AC rated voltage 0.6/1kV and below, mainly used in high-rise buildings, underground railways, nuclear power plants and important industrial and mining enterprises related to fire safety and fire rescue, such as emergency power supply to indoor fire fighting equipment, fire alarm equipment, signal lights, ventilation exhaust Power supply lines for smoke equipment, emergency elevators, etc. The rated power frequency voltage Uo/U is 0.6/1kV; the allowable long-term maximum working temperature of the cable conductor is 70°C for NH-VV and NH-VV22; NH-YJV and NH-YJV22 are 70°C; the ambient temperature when laying the cable should not be Below 0°C, the minimum bending radius is 20 times the outer diameter of the cable.
Specify the price USD 0 0
Product use: Widely used in large buildings, tunnels, petrochemical industries, power stations, mines and other places that have high requirements for fire protection. Prevent the fire from spreading rapidly on the cable line, avoid the expansion of fire accidents, and reduce losses. According to different flame retardant grades, flame retardant cables are divided into three categories: Class A, Class B, and Class C flame retardant cables.
Specify the price USD 0 0
Product introduction: This product has low capacitance and low inductance, and has excellent shielding performance and anti-interference performance. Therefore, the explosion-proof performance is better than general computer cables and control cables. It is suitable for intrinsic safety such as distribution systems and automatic detection and control systems with explosion-proof requirements. Transmission line in the cable. Use characteristics: 1 Rated voltage 450/750 and below. Cross-linked polyethylene insulation can be used in 0.6/1kV occasions. 2 The long-term allowable working temperature of the conductor of the cable: the working temperature of polyvinyl chloride and polyethylene insulation does not exceed 70°C. The cross-linked polyethylene does not exceed 90°C. 3 The laying temperature of the cable is not lower than -20℃. 4 The allowable bending radius of the cable: unarmored cable, not less than 6 times the outer diameter of the cable. Cables with armored or copper tape shielding structure shall not be less than 12 times the outer diameter of the cable. The flexible cable with shielding structure shall not be less than 6 times.
Specify the price USD 0 0
Suitable for many occasions such as middle and high-rise buildings, airports, ports, tunnels, etc. The maximum working temperature of the cable conductor: PVC insulated cable 70℃, XLPE insulated cable 90℃; when short-circuit (the longest time does not exceed 5s), the maximum temperature of the cable conductor does not exceed: PVC insulated cable 160℃, XLPE insulated cable at 250°C.
Specify the price USD 0 0
Product introduction:    Rated voltage 0.6/1kV and below agricultural moisture-proof direct-buried electricity adopts polyfine olefin material and compact conductor structure design, which has good resistance to lateral pressure, impact resistance, low loss, no soil pollution, and a more traditional price of polyvinyl chloride Insulated cables are cheap and other advantages, and designed for different users and use requirements, three types of sheath forms: phase separation, ribbon, and overall package. Specific places (rural environments) can be used instead of armored cables, and can be directly buried or laid overhead. . Use characteristics: 1 The rated voltage of the cable is 0.6/1kV and below, the maximum rated working temperature of the cable conductor is 70°C, and the maximum temperature of the cable body does not exceed 130°C during a short circuit (the longest duration does not exceed 5 seconds). 2 The cable laying temperature should not be lower than -10℃, and the minimum bending radius when laying the cable is: single-core cable 20 (D+d), multi-core cable 15 (D+d).
Specify the price USD 0 0
Product use: Mainly used in low-voltage power grid projects Use characteristics: 1. The rated working voltage of the cable is 0.6/1kV; 2. Working temperature: Polyvinyl chloride and polyethylene insulation does not exceed 70°C. Cross-linked polyethylene insulation does not exceed 90°C; 3. The ambient temperature during cable laying shall not be lower than -5℃; 4. The minimum bending radius of the cable is not less than 6 times the outer diameter of the cable.
Specify the price USD 0 0
Widely used in important places or densely populated areas such as subway projects, tunnels, nuclear power plants, substations, business centers, hotels, schools, hospitals, etc. Maximum long-term allowable working temperature of cable conductor:        Polyethylene insulation 70℃        Thermoplastic halogen-free low-smoke insulation 80℃        Chemical cross-linked polyethylene insulation 90℃        The cable processed by the irradiation cross-linking process can reach the maximum long-term allowable working temperature        90℃, 105℃, 125℃, 135℃ and 150℃.        The ambient temperature during cable laying should not be lower than -10°C.
Specify the price USD 0 0
Product Usage:    The function of compensating wires and cables for thermocouples is to extend the cold end of thermocouples and connect them with thermometers to form a temperature measurement system.      The product adopts imported high-quality PTFE insulation and sheath, and adopts advanced extrusion equipment and new process flow production line. It has excellent properties such as high temperature resistance, low temperature resistance, acid resistance, alkali resistance, corrosion resistance, and aging resistance. It can be immersed in oil and water for long-term use. Normal working temperature -40-275℃.
Specify the price USD 0 0
Signal transmission and control in electronic computers and similar electronic equipment Parameter range: The rated voltage U0/U of the cable is AC 450/750V and below or DC 1000V and below; the cable is allowed to be used for fixed laying or mobile use when the ambient temperature is -20~50℃ and the relative humidity is not more than 80%. The working temperature of the cable core Not higher than 70°C. The temperature during cable laying should not be lower than 0℃. Cable allowable bending radius: Cables for fixed locations: cables with no armor layer should be no less than 12 times the outer diameter of the cable; cables with armored layer structure should be no less than 15 times the outer diameter of the cable. Cables for mobile sites: should not be less than 8 times the outer diameter of the cable;
Specify the price USD 0 0
Product use: used for power transmission and distribution lines with a rated voltage of 35kV and below. It can be directly buried underground, in tunnels or pipelines, and used in humid environments, rivers and places with high groundwater levels. Product representation method: According to the representation method of cross-linked polyethylene insulated cables specified by the national standard, plus the additional characteristic representation method of this product ZSA or ZSB. The characteristic expression method is generally added before the cable model. ZSA means that the cable conductor and insulation filling are all designed with water blocking. The conductor and cable core have longitudinal water-blocking properties, and the cable has radial water-blocking properties. ZSB indicates that the conductor of the cable has no water-blocking structure, other cable cores have longitudinal water-blocking properties, and the cable has radial water-blocking properties.   The rated voltage of the cable is 35kV and below. Maximum rated working temperature of cable conductor: PVC insulation 70℃, XLPE insulation 90℃. When short circuit (the longest duration does not exceed 5 seconds), the maximum temperature of cable conductor does not exceed 160℃ for PVC insulation and 250℃ for XLPE insulation. Cable laying temperature is not Below 0°C, the minimum bending radius when laying the cable should meet the requirements of GB12706. Fully water-blocking cables (ZSA) can be used in areas with a lot of water such as rivers, and ZSB-class cables can be used in wet and rainy areas.
Specify the price USD 0 0
Suitable for steel, petroleum, chemical, power generation, metallurgy, aerospace and other places, fixed laying in the harsh environment of high temperature, low temperature and acid, alkali, oil, water and corrosive gas Maximum long-term service temperature of cable conductor:        PTFE Insulation F46 200℃     The highest ambient temperature applicable to the cable:        Fluoroplastic insulated PVC sheathed cable 105℃        Fluoroplastic insulated silicon rubber sheathed cable 180℃        Fluoroplastic (F46) sheathed cable 200℃     Environmental conditions during cable laying:        The ambient temperature of silicon rubber sheathed cable laying is not lower than -60℃        The environment temperature for laying PVC sheathed cables shall not be lower than 0℃.     The minimum bending radius of the cable is not less than the outer diameter of the cable:        PVC and fluoroplastic sheath 15 times.        Silicone rubber sheath 12 times        Soft structure silicone rubber sheathed cable 6 times
Specify the price USD 0 0
The products of our company include: silicone rubber insulated wire and cable, fluoroplastic insulated wire and cable, high and low temperature resistant wire and cable, special mine wire and cable, computer cable, wire for intrinsically safe system, cold-resistant, fire-resistant, flame-retardant, halogen-free and low-halogen Smoke wires and cables, etc.   Product Usage: This product is suitable for power lines and transmission and distribution lines with strict requirements on shielding performance, especially suitable for power supply or connection cables in variable frequency control transmission systems with rated voltages of 0.6/1kV and below. Use characteristics: 1. Completely symmetrical space structure design, the cable has excellent electromagnetic compatibility; 2. Low and uniform forward (reverse) sequence and zero sequence impedance, which greatly improves the quality of power supply compared with ordinary four-core cables; 3. High-density braided shielding and composite shielding design make the cable have good anti-electromagnetic interference and electromagnetic radiation performance, which is conducive to the application of new automatic short-circuit protection equipment; 4. Thoroughly shield the interference of high-order harmonic current components to other control circuits; 5. The cross-sectional design of the shielding layer reaches a certain ratio to the main core, which can be used as a PE grounding core; 6. The maximum working temperature of the cable conductor is compatible with the insulating material; 7. The bending radius of the cable is 15 times the cable diameter, and the flexible cable is 10 times the cable diameter; 8. The ambient temperature of the cable laying should not be lower than 0°C for the PTFE insulated cable, and the silicone rubber insulated and sheathed cable should not be lower than -20°C. Product model and specification
Specify the price USD 0 0
It is suitable for large-scale power station lead wires and urban underground main lines for power transmission and distribution. The long-term operating temperature of the cable conductor is 90°C; the maximum temperature of the cable conductor does not exceed 250°C during a short circuit (the longest duration does not exceed 5S).
Specify the price USD 0 0
It is suitable for power transmission and distribution lines with a rated voltage of 1~35kV.
Specify the price USD 0 0
Executive standard: GB14049-93 Product use: used for AC rated voltage 10kV, 35kV overhead power Use characteristics: 1. The long-term working temperature of the cable conductor does not exceed 90℃, and the maximum working temperature of the conductor does not exceed 250℃ when short-circuited (the longest duration does not exceed 5s); 2. The cable laying temperature is not less than -20℃; the allowable bending radius of the cable is not less than 20 times the outer diameter of the cable.
Specify the price USD 0 0
The cable can be produced in accordance with GB12527-90, GB14019, Australian standard AS1429, etc.   Product use: Used for overhead power lines with AC rated voltage U0/U of 0.6/1kV and below. Use characteristics: 1. The long-term working temperature of the conductor of the PVC insulated cable does not exceed 70℃, and the maximum working temperature of the conductor does not exceed 160℃ when short-circuited (the longest duration does not exceed 5s); 2. The long-term working temperature of the conductor of the cross-linked polyethylene insulated cable does not exceed 90℃, and the maximum working temperature of the conductor does not exceed 250℃ when short-circuited (the longest duration does not exceed 5s); 3. The cable laying temperature is not less than -20℃; the allowable bending radius of the cable is not less than 6 times the outer diameter of the cable.
Specify the price USD 0 0
Suitable for indoors, cable trenches, pipelines, direct burial, vertical shafts and other occasions and corresponding shielding occasions   The long-term allowable working temperature of the conductive core of the cable: PVC insulation is 70℃, XLPE insulation is 90℃; XLPE insulation can be used in 0.6/1kV occasions; the allowable bending radius of the cable: unarmored cable, not less than the cable 12 times the outer diameter. Cables with armored or copper tape shielding structure shall not be less than 15 times the outer diameter of the cable. The flexible cable with shielding structure should be no less than 6 times.
Specify the price USD 0 0
Product Usage:     Used for power devices, household appliances, small electric tools, instruments and meters, power and lighting circuits with AC rated voltage U0/U of 450/750 and below.     The largest section can produce 300mm2
Specify the price USD 0 0
This product is suitable for overhead antennas for communications. The largest section can produce 35mm2
Specify the price USD 0 0
The main purpose of this product: electrical equipment and electronic appliances or component wiring. The largest section can produce 800mm2
Specify the price USD 0 0
The test voltage is 75kV and below, and the operating temperature is below 70℃; contact with trees is not allowed; aluminum stranded wire is used for power supply lines with very small force and normal span; steel core aluminum stranded wire is used for high voltage or ultra-high voltage Large and long-distance transmission and distribution pipelines; soft steel-cored aluminum stranded wires are used in high-pressure or ultra-high-pressure transmission and distribution pipelines in non-, water-lake and other corrosive environments with salt, sand, sand and other corrosive environments
Specify the price USD 0 0
This type of product is mainly used for power system trunk transmission and distribution of high-power electric energy, including power cables with various voltage levels and various insulations ranging from 1 to 500kV. Our company’s products include: XLPE insulated power cables, PE insulated power cables, PVC insulated power cables, silane XLPE insulated power cables, weather-resistant insulated overhead lines, and various fire-resistant, flame-retardant, halogen-free, Low-smoke, water-blocking products. Product use: It is used for transmission and distribution of fixed-laying, AC rated voltage 1kV and below power transmission and distribution lines. The maximum rated working temperature of the cable conductor is 70℃; the cable laying environment temperature should not be lower than 0℃, and the minimum bending radius is: single-core cable: 20 (D+d); multi-core cable: 15 (D + d) where: D― ―The actual outer diameter of the cable d――The actual outer diameter of the cable conductor
Specify the price USD 0 0
Quick Details Model Number: GYTS Type: Fiber Optic Cable Place of Origin: Sichuan, China Brand Name: Aitong Number of Conductors: 4 Application: Duct, overhead Color: Black, customized Certification: ISO9001 Jacket Material: PE,LZSH, customized Diameter of cable: 8.9mm±0.2mm~14.7mm±0.2mm fiber type: single mode Use: Core network, Metropolitan area network, Access network Fiber count: 2-144
Specify the price USD 0 0
快速详细信息 型号:GJYXCH 2B6a 类型:光缆,尾纤跳线 产地:中国四川 品牌名称:Aitong 导体数:2 应用:通信系统 FTTH 数据传输 CATV 局域网 颜色:黑色,定制认证: ISO9001 护套材质:LSZH、PVC、定制光缆直径:(8.0mm±0.1mm)*(2.0mm±0.1mm)光纤类型:单模用途:网络工程安装通信机房连接器类型:SC、FC或定制工作温度:-40~+85℃
Specify the price USD 0 0
RG SERIES CCTV SECURITY Drop cable for CCTV application Characteristics 1 Optional Conductor: Bare Copper(BC), TC(Tinned Copper), Copper Clad Steel(CCS) Dielectric: Physical Foam PE, Solid PE Jacket: PVC or Sunlight resistant PVC jacket Swept test: up to 400MHz Shield: High shield to protect interference from outside.

The official Qoovee website helps you make profitable deals, find a supplier and manufacturer to grow your business. In the “Directory of suppliers” section you can find for yourself everything you need: Electrical equipment and parts from Russia, Kyrgyzstan, Kazakhstan, Turkey, Ukraine and other countries. Product categories are constantly updated. Wholesale suppliers are looking for wholesale purchases and partnerships and are ready for mutually beneficial cooperation.

Write to us, we are online!