Uninterruptible power supply on-line Element series, 2000 VA, 48VDC
Uninterruptible power supply on-line Element series, 2000 VA, 48VDC
Uninterruptible power supply on-line Element series, 2000 VA, 48VDC
Product description
UPS of the Element series, with built-in batteries 4x9Ah / 12V. Charge current up to 1.4 A. Power 1800W / 2000 VA The Element Series SNR Uninterruptible Power Supply protects sensitive electrical equipment from the most common power problems, including power failures, sags, surges, line noise, high voltage spikes, frequency fluctuations, and harmonic distortion. Power outages can occur at unpredictable times, and power quality can also change over time. Power problems are dangerous for IT equipment and can result in critical data corruption, loss of unsaved work sessions, and equipment failure - all of which can result in hours of downtime and costly repairs. These UPSs are ideal for protecting servers, telecommunications, networking and industrial equipment. Features: double voltage conversion technology provides complete equipment protection and sinusoidal output voltage in all operating modes, as well as zero switching time to the battery; output power factor 0.9; The UPS can work together with generators; Intelligent three-stage charging is used to extend battery life; supports ECO mode; cold start function; standard communication interfaces: one RS-232 communication port, one USB communication port, and an internal slot for installing an SNMP card or dry contacts; Outlet Outlet Segment Management that allows non-critical loads to be disconnected in battery mode to extend the runtime of critical loads; the ability to increase the battery life by using up to four additional external battery packs; for UPS models with built-in batteries, hot-swappable batteries are available; function of emergency shutdown through the port of remote emergency power-off (EPO - Emergency Power-off); all important information is displayed on the device screen: load power and battery status are displayed in dynamic images. It is very easy to monitor the operation of the UPS, when the UPS fails, the display shows an error code, and the equipment can be restored in the shortest possible time using the table of fault codes; The LCD display can change the orientation of the image in accordance with the type of installation of the case: vertically or horizontally; the height of all UPS models of the Element series is only 2U. Contents of delivery UPS user manual CD with software SNMP DL801 for UPS USB cable power cable (input and output) RS232 cable brackets, rack mount for installation in a rack of uninterruptible power supplies SNR, we offer you the universal SNR-UPS-RK slide. (Sold separately) The UPS data monitors the correspondence of the incoming phase and neutral, therefore, in the event of a discrepancy, they signal this with an audible signal once every two minutes. Turn the plug in the socket Oscillograms of electrical signals at the input and output of the UPS (yellow - at the input to the UPS, blue at the output of the UPS) UPS model SNR-UPS-ONRM-2000-S48 Power 2000 VA / 1800W Input parameters Phase Single-phase with ground Rated voltage 230VAC * Input voltage range 160-290 VAC Frequency range 46 - 54 Hz or 56 - 64 Hz (auto-sensing) Input Power Factor ≥0.98 Range in ECO mode 200VAC-240VAC U min disable ECO mode - 200 VAC / U min disable ECO mode - 204 VAC U max of ECO mode deactivation - 240 VAC / U max of ECO mode activation - 236 VAC Bypass voltage range 186VAC-252VAC U min bypass shutdown - 185 VAC / U min bypass shutdown - 195 VAC U max switching off Bypass mode - 252 VAC / U max switching on ECO mode - 246 VAC Rated current 8.7 A Input connection IEC320 C20-16A Output parameters Phase Single-phase with ground Rated voltage 220 VAC ± 2% (208, 230, 240 VAC optional) Frequency 50/60 Hz ± 1 Hz Output power factor 0.9 Crest Factor 3: 1 Harmonic distortion (line load) ≤3% Harmonic distortion (non-linear load) ≤5% Output sockets (IEC C13-10A) × 6 Efficiency (efficiency) in mains operation ≥ 87% at full load Efficiency (efficiency) in ECO mode ≥ 94% at full load Switching time (Utility ← → Battery) 0 ms Switching time (Utility ← → Bypass) < 4ms Battery parameters Battery voltage 48 Battery type 12V / 9Ah 4 pcs. consistently Back-up time at 50% load 11 minutes Battery charge current 1.4 A Charge voltage 54.8 Vdc ± 1% Charging time 8 hours up to 90% Battery protection Overcharge, overvoltage, short circuit protection UPS Features Overload capacity in mains mode 150% ± 5% <load ≤200% ± 5% after 300ms transfer to bypass and alarm 150% ± 5% <load ≤200% ± 5% after 300ms transfer to bypass and alarm Overload capacity in battery mode 108% ± 5% <load ≤150% ± 5% after 30s transition to emergency mode alarm 150% ± 5% <load ≤200% ± 5% after 300ms transition to emergency mode alarm Overload capacity in Bypass mode 130% ± 5% <load ≤150% ± 5% after 2 min transition to emergency mode alarm 150% ± 5% <load ≤200% ± 5% after 15s transition to emergency mode alarm Interfaces USB, RS-232, Internal SNMP card slot or dry contacts Environmental conditions and physical parameters Operating temperature 0 ° C - 40 ° C (recommended 15 - 25 ° C) Storage temperature -20 ° C - + 40 ° C Transport temperature -25 ° C - + 55 ° C Relative humidity 0 - 90% (non-condensing) UPS dimensions (WxDxH) 440mm × 552mm × 86.5mm Weight, kg 26.3 Noise level <55 dB Heat dissipation when operating from the mains, BTU / hour 346 Protection class IP20 IP20
Learn more

Uninterruptible power supply on-line Element series, 2000 VA, 48VDC - 56914

Check availability
525.03 USD/pcs 525.03 USD

Minimum order: 5 pcs

Supply ability: 10 pcs/per day

LiderTeam
Not verified supplier
Uzbekistan
Shipping information

Calculate and complete your cargo transportation worldwide using Qoovee Logistics.

Guaranteed shipment on time and secure payment Calculate shipping from Qoovee

Similar products

Suppliers in this category

All suppliers in the category
Contact supplier
Supplier:
"Узлегпром"
Write to us, we are online!