Product description
Cabinets for storing flammable liquids (flammable liquids).
The storage of flammable liquids in the laboratory requires certain conditions, since a fire of extremely hazardous substances in the room can lead to an explosion and irreparable consequences. A safe storage cabinet for flammable liquids is a necessary attribute of any laboratory. As long as the temperature inside the cabinet does not exceed the permissible norm, an explosion due to the ignition of flammable liquids will not occur. In an emergency, firefighters will have more time to clear the fire before it explodes.
FEATURES OF THE CABINET FOR SAFE STORAGE OF FLS
Cabinets for storage of flammable liquids are designed specifically to protect employees from unforeseen situations that may arise as a result of the ignition of hazardous liquids. There are some substances whose ignition temperature is too low. Even if the room temperature rises slightly, a flash may occur.
Special-purpose cabinets provide maximum isolation of reagents from temperature changes. In other words, they are a secure, specially designed safe for chemicals.
The acid storage cabinet is made of durable anti-acid steel sheets. It includes two buildings - external and internal. The first is made of refractory material, the second is made of a special material that prevents the development of corrosion.
Another component of the cabinet is a thermally expanding gasket, it provides insulation, its effect is manifested in the dynamics of temperatures. It expands itself in the event of a fire hazard, thereby sealing doorways.
Nomenclature of cabinets:
LVZh 600 cabinet;
LVZh 900 cabinet;
LVZh cabinet 1100;
LVZh cabinet 700V;
LVZH cabinet 1200V.
The models differ in the internal dimensions of the working area, weight, dimensions and storage volume.
Cabinets for storage of flammable liquids can be built into fume hoods and other laboratory furniture, be part of entire storage systems.
#npoarosa #npoarosa #lvzh #laboratory furniture #laboratory equipment #chelyabinsk # sankt-petersburg # moscow # yekaterinburg
Learn more
Check availability
569.79
USD/pcs
569.79
USD
Minimum order: 1 pcs
Supply ability: 45 pcs/per day
Ароса - лабораторная мебель и оборудование
Not verified supplier
Russia
Shipping information
Calculate and complete your cargo transportation worldwide using Qoovee Logistics.
Guaranteed shipment on time and secure payment Calculate shipping from QooveeSimilar products
NELSON Calibration
Indonesia
USD
5679.0/pcs
5679.0
Features: Yamato AW-47-115V: The Ultimate Benchtop Glassware Washer for Laboratories by NELSON Calibration
Efficient Cleaning: High-pressure spray nozzles effectively remove contaminants from glassware. Versatile Operation: Accommodates a wide range of glassware sizes and shapes. Automatic Detergent Dispensing: Ensures optimal cleaning results without manual intervention. User-Friendly Interface: Intuitive controls simplify operation and monitoring. Durable Construction: Stainless steel construction ensures longevity and reliability.
Specifications:
Voltage: 115V Power: 1800W Capacity: 47 liters Dimensions: 24″ x 24″ x 36″ Weight: 150 lbs
Product Overview:
The Yamato AW-47-115V Semi-Automatic Benchtop Laboratory Glassware Washer is an essential tool for laboratories requiring efficient and thorough glassware cleaning. Its advanced features and durable construction make it an ideal choice for a wide range of applications.
What’s in the Box:
Yamato AW-47-115V Semi-Automatic Benchtop Laboratory Glassware Washer Detergent dispenser Spray nozzles User manual
Benefits:
Time-Saving: Automates the glassware cleaning process, freeing up valuable time for other tasks. Improved Cleaning Quality: High-pressure spray nozzles ensure thorough removal of contaminants. Increased Productivity: Versatile operation allows for efficient cleaning of various glassware types. Enhanced Safety: Automatic detergent dispensing eliminates the risk of chemical exposure. Durable Investment: Stainless steel construction ensures long-lasting performance.
Value Proposition:
The Yamato AW-47-115V Semi-Automatic Benchtop Laboratory Glassware Washer offers exceptional value by providing:
Efficient and reliable glassware cleaning: Ensures accurate and consistent results. Time and labor savings: Frees up staff for more critical tasks. Improved safety: Reduces the risk of chemical exposure.* Durable construction: Provides a long-term investment.
Specify the price
USD
0
0
FEATURES: - The 40cm diameter sterilization chamber offers large space to meet various sterilization requirements. - The latest Inspiration microcomputer high-speed intelligent control system is highly reliable to not only realize complete control of the sterilization process, but also ensure convenient maintenance, query, calibration, recording and future scalability. — Special waste sterilization procedures have been established for effective sterilization of laboratory waste. — Thorough drying in accordance with CE standard. — Simple and clear control panel. — Several sterilization procedures and heating procedures are provided, such as sterilization, heating and drying of solids and liquids, melting and heating of agars. There are up to 60 cycles that can be created and saved for quick use. - Unique "eight-column evenly distributed" locking device is safer and more reliable than conventional locking devices.
BVM MEDICAL LIMITED
United Kingdom
USD
314.67 - 414.67/pcs
Description
Mobile support with micrometric control.
Placing controls manually by micrometer.
Dimensions: 185X145mm;
Travel: 25mm (X) x 25mm (Y);
Micrometric controls resolution: 0.01mm.
BVM MEDICAL LIMITED
United Kingdom
USD
1049.1 - 1349.1/pcs
Description
For applications subject to verification, also request initial verification at the same time because it cannot be done later. Factory verification, we need place of installation with zip code.
Indication of capacity. A rising strip of light indicates the weighing range still available
4-digit identification number, freely programmable via 2 keys
Robust and stable metal cover
Technical data:
Additional technical measurement data: 627- ABJ220-4M
Max measuring range: 220 g
Reading d: 0.0001 g
Reproducibility: 0.0001 g
Linearity: ± 0.0002 g
Stabilization time: 5 s
Sensitive deviation (° C): 2 * 10 ^ -6
Housing dimensions WxDxH: 225x315x330 mm
Housing material: metal
Windshield WxDxH mm: inside: 190x159x225 mm
Windshield material: glass
Packaging dimensions WxDxH (mm): 500x390x535
Gross weight kg: 9
Net weight kg: 7
Weighing pan dimensions (Ø / AxP): 8 cm
BVM MEDICAL LIMITED
United Kingdom
USD
372.86 - 472.86/pcs
Description
For applications subject to verification, also request initial verification at the same time because it cannot be done later. Factory verification, we need place of installation with zip code.
Large, backlit LCD display with 52mm high digits
Industrial quality: Ideal for long-lasting use in the industrial sector thanks to its stable construction and its robustness
Table base plate wall support for indicating device, standard
Weighing with tolerance range (check-weighing): Entry of an upper / lower limit value. An optical and acoustic signal facilitates the process of rationing, dosing or classifying by way of counting
Sum of weight values
Dynamic weighing: a stable mean value is created at the press of a key in the event of uneven ambient conditions or animal weighing
Technical data:
Max measuring range: 30 kg; 60 kg
Reading d: 10 g; 20 g
Reproducibility: 10 g; 20 g
Linearity: ± 10 g; 20 g
Stabilization time: 2 s
Sensitive deviation (° C): 5 * 10 ^ -6
Housing dimensions WxDxH: 560x300x490 mm (incl. Pole)
Housing material: plastic
Packaging dimensions WxDxH (mm): 470x800x240
Gross weight kg: 12
Net weight kg: 10
Weighing pan dimensions (Ø / AxP): 400x300x128 mm
BVM MEDICAL LIMITED
United Kingdom
USD
212.98 - 412.98/pcs
Description
Biological binocular microscope, lens 4x, 10x, 40x, 100x
Binocular biological microscope with 4x, 10x, 40x and 100x objectives. This type of equipment is recommended for research centres, laboratories or hospitals. It allows for viewing in detail cells, bacteriae, fungi or tiny tissues.
Lenses:
Magnification: 10x
Focal length: 25
Lens diameter: 18 mm / 0.7 in
Features:
Head: binocular
Swivel: 360 °
Inclination: 45 °
Eyepieces:
WF 10x18 mm (2 units)
WF 16x (2 units)
Objectives: plan achromatic 4x, 10xPh, 40xPh, 100xPh (immersion).
Revolving nosepiece: quadruple
Stage: DIM 160 x 142 mm (6.3 x 5.6 in), movement range 76 x 52 mm / 3 x 2 in
Focus range: 14 mm / 0.5 in
Condenser: 1.25 NA Abbe with centering system
Illumination: white LED, with brightness control
Dimensions:
Length: 140 mm / 5.5 in
Width: 190 mm / 7.48 in
Height: 350 mm / 13.8 in
Weight: 3 kg (6.6 lb) approx
BVM MEDICAL LIMITED
United Kingdom
USD
309.4 - 339.4/pcs
Micromotor for podiatry model Micronam300 which can reach a maximum speed of 35000 rpm. Features an ergonomic and functional design. Moreover, it has an automatic stop switch in order to avoid malfunctions.
BVM MEDICAL LIMITED
United Kingdom
USD
120.8 - 127.8/pcs
Description VORTEX shaker with speed control
Features:
Can work continuously or discontinuously by contact
Analogue speed control in the range of 0 - 2500 rpm
Clicking adapter fixing system providing security
Strong housing in casting with good stability
Silicon pads and steel base specially designed to absorb the vibrations
Eccentric wheel bearings
Plate dimensions: 182x450mm
Technical specifications:
Power(W)
60
Shaking movement
orbital
Diametr of shaking orbit (mm)
4
Allowable working time
100 %
Rango Velocidad (r.p.m.)
0 - 2500
Precisión ajuste de velocidad (r.p.m.)
Analógico
Tipo de funcionamiento
modo continuo / modo por contacto
Dimensiones (L x l x h) (mm)
127 x 130 x 160
Peso Weight (Kg)
3,5
Clase de protección según DIN EN60529
IP 21
BVM MEDICAL LIMITED
United Kingdom
USD
245.35 - 300.35/pcs
Description Single Arm Base head supports.Measurements:
Base: 230 x 230 mm
Vertical bar column: Ø32x380mm
Horizontal arm: 430 mm
BVM MEDICAL LIMITED
United Kingdom
USD
105.61 - 135.61/pcs
Description
Printer for autoclaves 922.
Features:
External Printer: Prints the details of the programme cycle.
Includes 1 paper roll
Measures:
Height: 7.2 cm
Width: 8.5 cm
Depth: 11.5 cm
BVM MEDICAL LIMITED
United Kingdom
USD
1008.3 - 1118.3/pcs
Description
Autoclave Black Dragon 12 liters class B for tattoo studios.
Programmes:
Programmes
Temperature
Pressure
Sterilisation time
Total time
Type
Max. load
Max. load per tray
Solid
134 0C
210 kPa
4 min
14-30 min
Solid unwrapped
4 Kg
1.2 Kg
1210C
110 kPa
20 min
30-45 min
Wrapped
134 0C
210 kPa
4 min
30-45 min
Solid unwrapped
3.5 Kg
1.1 Kg
121 0C
110 kPa
20 min
35-55 min
Solid or hollow simple wrapped
3.5 Kg
1.1 Kg
Liquid
134 0C
210 kPa
10 min
30-55 min
Liquid
0.80 kg
0.25 kg
121 0C
110 kPa
30 min
35-60 min
Textile
134 0C
210 kPa
8 min
30-50 min
Porous unwrapped
1 Kg
0.3 Kg
Porous simple wrapped
0.75 Kg
0.2 Kg
121 0C
110 kPa
30 min
40-60 min
Porous double wrapped
0.5 Kg
0.15 Kg
Hollow simple wrapped
3.5 Kg
1 Kg
Solid or hollow double wrapped
1.5 Kg
0.5 Kg
Prion
134 0C
210 kPa
18 min
30-50 min
Porous unwrapped
0.1 Kg
0.3 Kg
Porous simple wrapped
0.75 Kg
0.2 Kg
Porous double wrapped
0.5 Kg
0.15 Kg
Hollow simple wrapped
3.5 Kg
1 Kg
Solid or hollow double wrapped
1.5 Kg
0.5 Kg
B&D test
134 0C
210 kPa
3.5 min
22-35 min
-
-
-
Helix test
134 0C
210 kPa
3.5 min
22-35 min
-
-
-
Vacuum test
-
-
-
18-20 min
-
-
-
Safety:
A cycle will not start unless the door is firmly closed.
An automated system with double hydraulic locking device prevents the door from opening while chamber is pressurized.
The safety valves prevent overpressure in the generator and in the chamber.
A safety thermostat prevents overheating in the chamber and in the generator.
An automatic safety lock prevents accidental opening of the door during the sterilisation. A power protector automatically cuts off power in case of short circuit or if power supply is not very stable.
The failure alarm indicates a cycle failure and provides an error code.
The door alarm indicates that the door is not properly closed.
The low water alarm indicates when the water tank is empty or too full.
Technical features:
Power supply: 220-240V; 50/60Hz; 10A
Chamber: 200 x 360 mm
Breaker: F16A / 400V
Nominal power: 2200VA
Sterilisation temperature: 121 0C / 1340C
Capacity of the distilled water tank: 2.5 L
Working temperature: 5 0C / 40 0C
Working relative humidity: Max. 80%, non condensing
Overall dimensions: 414 x 365 x 570 mm
Net weight: 51 Kg
Max. noise level: <70 dB
Atmospheric pressure: 76 / 106 kPa
Components:
Distilled water tank
LCD display
Control panel
Main power switch
Drain connector (distilled and used water tank)
USB port
Safety valve
Ventilation grid
Circuit breaker
Power cable
Rating plate
Accessories included:
Steriliser
USB
3 instrument trays
Tray rack
Tray holder
Door adjustment tool
2 draining hoses
Door gasket
User manual
Standards:
93/42/EEC Directive on Medical Devices.
97/23/EEC Directive on Pressure Equipment.
EN 13060 Small Steam Sterilisers.
EN 61326, EN 61000 Electromagnetic Compatibility.
EN 61010-1, UL 61010-1 Safety requirements.
EN 61010-2-040, IEC 61010-2-040 Specific requirements for steam sterilisers used for treatment of medical materials.
AUTOCLAVE - step by step:
Open the door, take the tools and accessories that are within the sterilisation chamber, remove the wrapper and clean them.
Connect the power cord to a suitable power source.
Connect the printer (optional. It is sold separately, ).
Switch on: The main switch is located on the right bottom area in the front panel.
Once activated, the LCD screen is on, where basic operation icons such as the position of the door, the water level, the sterilisation programme, date, time, etc. appear.
Fill tank with distilled water.
Remove the top lid and fill, if you hear a signal, it means that you exceeded the permitted level of water in the tank, please stop immediately and drain the amount of water necessary for the signal off.
Preparation of instruments:
Place instruments made of different materials in different trays, however take care to separate them before sterilisation.
If the instruments are not stainless steel, put some sterilisation paper between the tray and the instruments.
Do not allow direct contact between instruments of different materials.
Verify that all instruments are in correct position.
Place instruments such as lenses, containers, tubes, etc. inverted, so that water does not stagnate within them.
Do not overload the trays beyond their limit.
Do not overlap the trays on top of each other, or put them in direct contact with the wall of the sterilisation chamber.
Do not use metal clips or pins, this may impair the operation of the steriliser.
Wrap the instruments one by one. If you need to wrap several instruments together, make sure that they are made of the same material.
Seal the pouch with special adhesive tape for sterilisation or use a heat sealer.
Make sure that the pouch is properly positioned within the chamber on the trays (resting on the plastic part).
Choose the sterilisation programme.
Start the sterilisation cycle.
After selecting the sterilisation programme, insert instruments into the chamber on the trays, using the supplied plastic handle.
Once the instruments are placed within the chamber, close the door by turning the knob.
Caution: make sure to close the door, otherwise the steriliser displays an alarm and can not start or the programme stops during the cycle.
Start the sterilisation programme.
Press the start button, then the steriliser starts operating during approximately 30-75 minutes.
Sterilisation cycle finished.
After finishing the sterilisation cycle, the printer (not included*) will print the full report automatically and the data will be saved in the USB memory (.txt format).
After the pressure drops to zero, you can open the door and remove the instruments. The steriliser alerts by a beep once the sterilisation cycle is completed.
Caution: Use the supplied plastic handle for supporting trays when you take out the instruments.
IMPORTANT: Do not reuse used water.
Installation:
There must be at least 10 cm of free space around the steriliser, 25 cm at the top, and enough room to open the door.
The place where the steriliser is used must have proper ventilation.
The steriliser must be placed on a stable surface and at an appropriate height for handling.
Do not cover or block the lateral outlets or the outlet air grid of the condenser fan.
Do not place the steriliser near water sources.
Keep away from heat sources.
Example of printed report:
================================Programme: WRAPPED
Temperature: 134CPressure: 206.0 kPaDrying time: 08minSterilisation time: 4.0Min--------------------------------Time Temp. pressureStart 12:28:17 089.0CT1: 12:31:32 087.1C -075.0kPaT2: 12:33:43 110.2C 052.0kPaT3: 12:36:37 088.9C -080.0kPaT4: 12:39:20 114.7C 053.7kPaT5: 12:43:37 087.9C -080.0kPaT6: 12:50:40 134.8C 206.0kPaTS: 134.7C 209.5kPaMax. Temperature: 135.2CMin. Temperature: 134.3CMax. Pressure: 214.0kPaMin. Pressure: 204.9kPaT7: 12:54:39 134.4C 211.4kPaT8: 12:57:36 102.1C -060.0kPaT9: 12:59:54 098.2C -060.0kPaEnd 13:04:07 102.4C--------------------------------Cycle No .: 00017Result: successDate: 07/06/2014SN: E54723operator:================================
BVM MEDICAL LIMITED
United Kingdom
USD
594.72 - 794.72/pcs
Description
Autoclave Prestige 2100 Classic 9 litres.
Characteristics:
Designed to sterilize unwrapped solid instruments.
Capacity 9 Litres.
With basket for instruments sterilisation
Technical specifications:
Height
335 mm
Width
340 mm
Weight
4.5 Kg
Capacity
9 litres
Dimensions of the internal chamber
(depth / height) 210/230 mm
Maximum length of the instruments
228 mm
Maximum weight of load
3.0 Kg
Operating pressure
1,4 bar
Voltage
230V
Power
1500W
Frequency
50-60Hz
Temperature
121º
Sterilisation time
11 minutes
Total cycle time
22 minutes
Water volume
0.75 litres
Suppliers in this category
All suppliers in the category
Product:
Supplier:
Min. order:
Directory
Marketing department:
Marketing department:
Marketing department:
Information
Inform manager that you found the product on Qoovee
The contact details of the supplier is not available!
Send message